Description
Tubular type level gauge are widely used for low pressure services up to 5Kg/cm2 and maximum temperature of 100°C. Check balls are built in the upper and bottom valve \s to stop flow instantaneously when the glass is broken. A cylinder like sheet metal protector is available to prevent glass breakage from external sources. For those gauges of their center to center dimensions in excess of 1,800mm, intermediate couplings are used to connect tubular glasses. Depending on nature of liquids, tubes made of various plastic resing are also available. Tubular glass with a linear red coating on the back is available to make level observation more clear.
Model
Specification
- P.F.A & GLASS TUBE SIZE: OUT SIZE Dia: 19mm, IN SIDE Dia: 15mm
- STANDARD CONNECTION: VESSEL: 20A JIS 10Kgf/cm2 RF FLANGED DRAIN : PT 1/2″
- CENTER TO CENTER RANGE: 300~2000mm
- VISIBLE LENGTH: C to C minus 150mm
- GLASS LENGTH: C to C minus 35mm WORKING PRESSURE: 5Kgf/cm2G(MAX)
- WORKING TEMPERATURE: 100 DEC (MAX)
- SHELL TEST PRESSURE: 7Kgf/cm2G
- OPTIONAL CONNECTION:
VESSEL:
1/2″ JIS or NPT MALE
1/2″ MALE FOR WELDING
FLANGE to REQUIREMENTS